Abstract

The adsorption capability of carbon dioxide on 13X molecular sieve (13XMS) was investigated in a fixed-bed apparatus with two-road gas mixing system by dynamic column breakthrough method with helium as carrier gas at helium purification conditions of high-temperature gas-cooled reactor (HTGR). Experiments were performed at temperatures of 5°C ∼35 °C and low carbon dioxide partial pressure range of 10∼150Pa. By analyzing the breakthrough curve, both equilibrium adsorption capacity and kinetic adsorption capacity at breakthrough point were determined. Based on mass-transfer zone model, the experimental breakthrough curves at different operation conditions were analyzed. The carbon dioxide isotherm on 13XMS was fitted well by Langmuir model and the enthalpy of adsorption of carbon dioxide was estimated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.