Abstract
Performance and internal flow of a direct drive turbine (DDT) model for wave power converter system is investigated experimentally. Three kinds of test turbine model are adopted for the examination. Test results show that rotational speed of test runner, differential pressure between front and rear nozzle passages and passage flow rate increase by the increase of wave height and wave period. Maximum output power and best efficiency of the test turbine model locate at the different rotational speed by wave height. Installation of front guide wall and rear water reservoir of the test turbine improves the turbine performance. Large passage vortex occurs both at the front and rear nozzle passages in turn by reciprocating flow in the internal flow passage of the turbine model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.