Abstract
To study the concentration characteristics of mechanical vapor compression (MVC) technology on the wastewater concentration process, a single-effect MVC system for concentrating dimethylacetamide wastewater was investigated. The performance of the MVC experimental system was evaluated under different levels of distillation pressure and concentrations of the raw solution. We demonstrated that under conditions of atmospheric distillation (evaporating temperature was 100°C), the COP and distilled water production rate of the experimental system reached 20.17 and 70.80kg/h, respectively. In the distillation operating cycle, the DMAC solution was concentrated from 6% to 83.5%. In addition, when the system was under vacuum conditions (evaporating temperature was 55.8°C), the COP and distilled water production rate were 5.44 and 18.2kg/h, respectively, and the concentration of the DMAC dilute solution was only 0.2%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.