Abstract
Thermal conductivity of refrigerant R-409A in vapor phase was studied in the range of temperatures 306–425 K and pressures 0.12–1.33 MPa. Measurements were performed with the stationary method of coaxial cylinders. Uncertainty of experimental data on thermal conductivity was 1.5–2.5 %, and errors of temperature and pressure measurements did not exceed 0.05 K and 4 kPa, respectively. Approximating dependence of thermal conductivity on pressure and temperature was obtained. Thermal conductivity on dew line and in ideal gas state was calculated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.