Abstract

Thermal conductivity of refrigerant R-409A in vapor phase was studied in the range of temperatures 306–425 K and pressures 0.12–1.33 MPa. Measurements were performed with the stationary method of coaxial cylinders. Uncertainty of experimental data on thermal conductivity was 1.5–2.5 %, and errors of temperature and pressure measurements did not exceed 0.05 K and 4 kPa, respectively. Approximating dependence of thermal conductivity on pressure and temperature was obtained. Thermal conductivity on dew line and in ideal gas state was calculated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.