This paper presents extensive temperature measurements obtained during a period of 4 years in an integral solid slab prestressed concrete bridge deck. There is very little experimental information available for this bridge typology. The quality of the measured temperature data are validated by comparing experimentally measured displacements at the ends of the bridge with theoretical displacements determined with the recorded temperature components. The measured temperatures are also compared with common design parameters made considering the specifications for thermal actions proposed by Eurocode 1. The results corroborate that the Eurocode 1 formulations are generally adequate to represent thermal actions on bridges; however, it may need to be complemented to define maximum and minimum temperatures for bridges in locations with daily temperature variations greater than 10°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.