The article presents the experiment in studying a new criterion of lighting quality based on spatial and angular distribution of luminance proposed by the Lighting Engineering sub-department of NIU MPEI. The experiment studies correlation between expert evaluations of lighting quality at 21 stations of the Moscow Metro with analysis based on the criterion of quality of RAW-format luminance photographs of the stations made by means of a camera and adjusted according to luminance measured by a luminance meter. The obtained photos were processed using the proposed criterion. The article presents design of station models and calculations made by means of DIALux software and the programme developed (as part of the work) on the basis of local evaluations. It is demonstrated that the proposed criterion allows us to take account of extended veiling reflections and may be considered as enhancement of the unified glare rating UGR.