Abstract

Particleboards are used in the manufacturing of furniture and are often part of the interior of buildings. In the event of a fire, particleboards are a substantial part of the fuel in many building fires. The aim of the article is to monitor the effect of radiant heat on the surface of particle board according to the modified procedure ISO 5657: 1997. The significance of the influence of heat flux density and particle board properties on its thermal resistance (time to ignition) was monitored. Experimental samples were used particle board without surface treatment, with thicknesses of 12, 15, and 18 mm. The samples were exposed to a heat flux from 40 to 50 kW·m−2. The experimental results are the initiation characteristics such as of the ignition temperature and the weight loss. The determined factors influencing the time to ignition and weight loss were the thickness and density of the plate material, the density of the radiant heat flux and the distance of the particle board from the radiant source (20, 40, and 60 mm). The obtained results show a significant dependence of the time to ignition on the thickness of the sample and on the heat flux density. The weight loss is significantly dependent on the thickness of the particle board. Monitoring the influence of time to ignition from sample distance confirmed a statistically significant dependence. As the distance of the sample from the source increased, the time to ignition decreased linearly. As the distance of the sample from the source increased, the time to ignition increased.