The electrical potential technique was applied to monitor the crack initiation and propagation in LY12-CZ plates. The feasibility of this method was validated by a simulation experiment firstly. Then fatigue crack monitoring experiment based on LY12-CZ aluminum alloy center-hole plate specimen was carried out. After a special coating sensor was prepared on the monitoring area of the specimen by surface technology, a set of fatigue crack monitoring experiments were carried out. The changes in the potential values of the coating sensor resulting from crack damage were documented. Since the property of the coating sensor and the introduced current were constant, the measured voltage values would only relate to the crack’s length and position. Based on the experimental results, the relation curves between voltage values and crack lengths were obtained, and a set of empirical formulae were deduced.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.