Abstract

This study proposed a novel experimental platform to conduct dynamic loading tests of a truncated model steel catenary riser (SCR) within the touchdown zone (TDZ). The facilities of the platform, including a soil tank, a loading system, and a soil stirring system, were introduced in detail. The parameters of the test were determined through the simulation of an in situ riser. A steel pipe was adopted as the model riser, with its outer diameter equaling that of the prototype SCR. Before executing the dynamic loadings, the model riser developed its static configuration under the submerged weight and applied bending moment. Subsequently, cyclic vertical and lateral displacement loads were applied to the truncated point. The test results showed that when the vertical loading amplitude increased from 200 mm to 300 mm, the stress ranges at the front of the model riser increased by more than 100%, whereas the stress range only differed by less than 5% under different loading periods. Numerical models of the SCR were built based on the vector form intrinsic finite element (VFIFE) method. High similarities between the test and simulation results proved the reliability of the nonlinear soil model and the numerical model. During the test, a seabed trench was developed with a depth of 0.71 D and a width of 0.48 D, and its shape was similar to the in situ trench.