We have set up a coherent population trapping (CPT)-based atomic magnetometer experimental system worked with 87Rb atoms, and with this system experimentally investigated the behaviour of a CPT magnetometer prototype proposed by us, which worked with the atomic energy level modulation scheme. Through systematical comparison with generally used microwave frequency modulation scheme, the experimental results reveal that the energy level modulation scheme not only extends the detection range, but also improves the sensitivity of magnetic field detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Physics B: Atomic, Molecular and Optical Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.