Abstract

The temperature and external AC magnetic field dependence of AC magnetization losses of MgB2 wires were studied. Temperature was varied from 18K to 40K and external magnetic field of frequencies 72Hz and 144Hz from 8mT to 70mT with orientation perpendicular to the wire axis. To clarify the influence of the wire construction on AC loss, single and six filament untwisted samples of length ∼50mm were examined. For this purpose unique experimental apparatus created by the combination of original calibration-free measuring system designed for ac magnetization loss measurement and non-magnetic vacuum vessel with two-stage cryocooler for sample cooling was used. It was found, that for monofilament sample hysteretic AC losses was dominated in comparison to untwisted six-filaments sample, where coupling losses confirmed by frequency dependence were dominated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.