This paper describes the measurements and analysis of an experimental campaign performed in an urban street canyon in Athens, Greece. A number of field and indoor experimental procedures were organized during summer 2002 aiming at the investigation of the impact of urban environment on the potential of natural and hybrid ventilation. The present study is focused on the experimental investigation of thermal characteristics of a typical street canyon, oriented in ESE–WNW direction, under hot weather conditions. The temporal and spatial distribution of air and surface temperatures is examined. Emphasis was given on the vertical distribution of air and surface temperatures and the air temperature profile in the centre of canyon under different weather conditions. The measured surface temperature differences across the street reached almost 30 °C and this favored the overheating of lower air levels. Buoyancy generated mainly from asphalt-street heating resulted in the development of the predominant recirculation inside the street canyon.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.