Abstract

A study of a cylindrical core test facility (CCTF) test was performed for modeling the system behavior during the reflood phase of a PWR-LOCA and the following conclusions were obtained: (1) With the exception of some points, the observed phenomena are similar to a model derived from an evaluation model for a PWR safety evaluation. (2) The different points are the water accumulation in the upper plenum, the ECC bypass in the downcomer, the reduction of the effective downcomer head and the pressure drop at the broken cold leg nozzle and in the inter-connected pipes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.