Abstract

An improved diversion-cone is designed to suppress subsurface vortices in pump intake. In experiment, the influences of size and location of the improved diversion-cone on the subsurface vortices in pump intake were studied. Experiments were conducted in a rectangle intake and 12 operating points were carried out, and the vortex frequency and vortex location were also measured. The results show that the new improved diversion-cone employed in the experiments has obviously positive effect in suppressing the generation of subsurface vortices. It is also found that the lower distance between the pump bell and the improved diversion-cone, the more frequency of free surface vortices occurred.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.