Abstract
An experimental investigation on solar chimney used for heating under climate of Iraqis carried out. Experiments were conducted on the chimney installed on vertical wall withabsorber plate placed at the front side of the air gap. The solar chimney attached to room ofdimensions (2.5×1.29×1.07) m. The chimney is studied to measure the effect of the air gapwidth with constant height of (1.07 m). Three widths are tested, namely, 0.2 m, 0.3 m and0.4 m. The experimental results showed that the solar chimney can achieve about (13 °C)difference in temperature between indoor and outdoor as well as it gives acceptabledifference in partial cloudy days. The results also indicated that the best performance ofsolar chimney is with 0.3m air gap width.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: THE IRAQI JOURNAL FOR MECHANICAL AND MATERIALS ENGINEERING
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.