Abstract
Abstract In Prototype Gen IV Sodium-cooled Fast Reactor (PGSFR), there are two types of sodium-to-sodium heat exchanger, namely, Intermediate Heat Exchanger (IHX) and Decay Heat Exchanger (DHX). The role, function, and size of each heat exchanger are different, but both heat exchangers are designed by the same computer code, SHXSA, developed at KAERI. In previous work, the design code and related correlations were validated under DHX operation conditions (low Pe number range). However, the IHX operation condition is beyond this range (Pe > 150), and the heat transfer performance test was extended by modifying the facility. The experiments under large mass flowrate conditions were conducted, and the heat transfer rate of the tube-side and shell-side resulted in good agreement with the code calculation. The uncertainty analysis results were also included, and the discrepancies were −0.68 to 0.26% and −2.92 to 1.04% for the outlet temperature and heat transfer, respectively.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.