Abstract

AbstractAn experimental study was conducted to investigate the behavior of deep coupling beams of span‐to‐depth ratio (1·17) fabricated according to the newly proposed plate‐reinforced composite (PRC) coupling beam design. Three PRC coupling beams of small span/depth ratio fabricated based on different approaches for load transfers between steel plates and reinforced concrete (RC) were tested under reversed cyclic loading. This paper presents the experimental results and compares the overall performance of these three specimens with two geometrically identical RC coupling beam specimens, one with diagonal reinforcement and the other with conventional reinforcement details, tested by previous researchers. It was found that the performance of PRC deep coupling beams of small span‐to‐depth ratio with properly designed plate anchorage in the wall regions can be comparable to that of diagonally reinforced coupling beams while being able to achieve a higher shear capacity without causing the problem of steel congestion. The proper design approach for the plate anchorage of PRC coupling beams was also identified. Copyright © 2007 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.