Abstract

This paper presents experimental data for the performance of two oblong, straight, air-air ejectors with 4-ring oblong entraining diffusers. The effects of inlet swirl angle, nozzle diameter and flow temperature on the ejector pumping, back pressure, wall pressure distribution, diffuser pressure recovery and surface film cooling effectiveness were studied. The experiments were carried out on a hot gas wind tunnel that could provide primary mass flow rates up to 2.2 kg/s at ambient temperature and 1.8 kg/s at 500°C. Velocity, pressure and temperature were measured in the annulus upstream of the primary nozzle, on the mixing tube and diffuser walls, at the diffuser gap inlets and at the diffuser exit. A comparison between the performance of the oblong ejector and a round ejector indicated that for a short length ejector, the oblong ejector provided better overall performance in terms of pumping and velocity and temperature distributions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.