Abstract

The present study focused on the monthly or annual 41Ar activity release rate and ground level activity concentration measurement including the estimation of public dose level at the ground and stack positions of the Bangladesh Atomic Energy Commission TRIGA Research. During the experimental work, a Geiger-Muller (G-M) counter was used for the air sample count rate study. The experimental results demonstrated that the obtained maximum monthly or annual 41Ar activity release rate (2.48 × 1010 Bq/month or 6.25 × 1011 Bq/year) and monthly maximum ground level 41Ar activity concentration (6.40 × 101 Bq/m3) were within the permissible limits set by the regulatory body. This report also confirmed that the estimated public dose levels (0.29 mSv/yr and 0.0002 mSv/yr) at the stack and ground positions were far below the IAEA acceptable limit (1.0 mSv/yr) which was significant for the research reactor safety.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.