Abstract

The Helmholtz resonance technique was applied to a liquid level gauge for liquid hydrogen to confirm the applicability of the technique in the cryogenic industrial field. A specially designed liquid level gauge that has a Helmholtz resonator with a small loudspeaker was installed in a glass cryostat. A swept frequency signal was supplied to the loudspeaker, and the acoustic response was detected by measuring the electrical impedance of the loudspeaker’s voice coil. The penetration depth obtained from the Helmholtz resonance frequency was compared with the true value, which was read from a scale. In principle, the Helmholtz resonance technique is available for use with liquid hydrogen, however there are certain problems as regards practical applications. The applicability of the Helmholtz resonance technique to liquid hydrogen is discussed in this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.