Abstract
The experimental study was carried out to investigate the gasification of urotropine (hexamethylenetetramine) in a low-temperature solid fuel gas generator under varying inlet gas flows. Nitrogen was applied as the filter gas. The filter gas flow was varied from 0.6 to 1.4 L/s with a step of 0.2 L/s. The inlet gas's initial temperature was equal to 910 K. It was shown that with an increase in the nitrogen flow, the fuel gasification time decreased. Increasing the flux of inlet nitrogen from 0.6 to 1.4 L/s results in an increase in the average urotropine gasification mass rate from 0.63 to 1.61 g/s. When the initial nitrogen flow is raised, the rate of fuel gasification increases almost linearly. Studies have demonstrated that the proportion of mass flows between urotropine gasification products and nitrogen remains constant regardless of the incoming gas flow. The mass flow ratio remains steady at approximately 0.9 g/g when the incoming gas flow is altered. It has been shown that the gaseous products of urotropine gasification consist of nitrogen with a small amount of hydrogen and hydrocarbons. The content of simple gaseous products does not exceed 4% vol.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.