Abstract

The thermosyphon is a type of heat exchanger that has been widely used in many applications. The use of thermosyphons has been intensified in recent years, mainly in the manufacture of solar collectors and various industrial activities. A thermosyphon is a vertical sealed tube filled with a working fluid, consisting of, from bottom to top, by an evaporator, an adiabatic section, and a condenser. The study of geyser-boiling phenomena, which occurs inside the thermosyphon is of extreme importance, therefore the experimental analysis of the parameters related to the two-phase flow (liquid-steam), such as void fraction, bubble frequency, bubble velocity, and bubble length are necessary, since these parameters have a significant influence on heat transfer. In this work, a pair of wire mesh sensors was used, a relative innovative technology to obtain experimental values of the reported quantities for measuring these parameters of slug flow in thermosyphons. An experimental set-up is assembled and the sensors are coupled to the thermosyphon enabling the development of the experimental procedure. Here is presented an experimental study of a glass thermosyphon instrumented with two wire-mesh sensors, in which the aforementioned slug flow hydrodynamic parameters inherent to the geyser type boiling process are measured. It was measured successfully, as a function of the heat load (110, 120, 130, 140, and 150 W), the void fraction (instantly and average), liquid film thickness, translation velocity of the elongated bubbles, lengths of the bubbles, and the liquid slug (displaced by the bubble rise up). It was observed that the higher the heat load, the lower is the bubble translation velocity. For all heat loads, based on the measured length of liquid slug (consequent displacement of liquid volume), caused by bubbles rise from evaporator to condenser, it could be affirmed to some extent that both boiling regime (pool and film) exist in the evaporator. The measured average void fraction (80%) and liquid film thickness (around 2.5 mm) during the elongated bubble passages were approximately constant and independent of the heat load.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.