Abstract

The present work is aimed at the experimental measurement of the two-phase heat transfer coefficient in the intermittent horizontal gas-liquid flow pattern, as well as its comparison with some existing correlations. The intermittent flow pattern is very common in oil production flow lines. In order to reach this objective an experimental apparatus was built, consisting of a 5 cm i.d., 6.0 m long pipe test section fed up with several air-water mixtures pre-heated at different inlet temperatures. Heat transfer was accomplished by surrounding the pipe with a cooling water jacket under various inlet flow rates and temperatures, flowing co-currently with the central pipe gas-liquid mixture. The heat transfer coefficient was experimentally determined and compared with four published correlations. Among then, a mechanistic model was selected for further improvement, with very satisfactory results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.