Abstract

Laminar free convection heat transfer from vertical and inclined arrays of horizontal isothermal cylinders in air were investigated experimentally. Experiments were carried out using a Mach-Zehnder interferometer. For the vertical array, the cylinder spacing (center to center) varied from 2 to 5 cylinder diameter. The same range of vertical spacing also was used for the inclined array. The horizontal spacing varied from 0 to 2 cylinder diameter in the inclined array. The Rayleigh number based on the cylinder diameter varied between 103 and 3× 103. The effect of vertical and horizontal cylinder spacing and Rayleigh number on the heat transfer from each individual cylinder and the whole array were investigated. It is found that the free convection heat transfer from any individual cylinder in the array depends on its position relative to the others. Heat transfer correlations have been developed for any individual cylinder in the vertical and inclined arrays and for the arrays. Also the experiment was carried out on a single cylinder for a comparison with the results from other research.