Abstract

In this study, we investigated the value of the loss coefficient, ζ23, at the exit of the rotor ventilation ducts when air coolant flows from the rotor ventilation ducts to the rotor-stator air gap by measuring the distribution of static pressure on the surface of the rotor and the stator and on the wall of the cooling duct of air cooled generators, by using a scale water model. Protuberant type rotor wedge was proposed and they performed much better than the flat type of rotor wedge for ventilation cooling. From the experimental results, for the protuberant type rotor wedge, the fluid can flow from the exit of the rotor cooling duct into the air gap with a small pressure loss, since the fluid near the rotor surface is separated from the rotor surface by the triangular protuberance and the static pressure above the exit of the cooling duct is less than that in the rotor cooling duct. The experimental results of the pressure loss and the results of numerical analysis which will be reported in another paper(1), were in good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.