Abstract
This paper presents a delayed feedback control scheme for eliminating chaotic behaviour in a peak current-mode controlled DC–DC boost converter operating in the continuous current conduction mode. Experimental results and FORTRAN simulations show the effectiveness and robustness of the scheme.