Abstract
Cavitation tests have been carried out for helical inducer with various blade lengths. Effects of inducer blade lengths on head characteristics and cavitation induced oscillation phenomena are described in the present paper. The oscillation occurring in the case of inducers with lower solidity less than 1.0 differs from that with the solidity of 2.0. Change of the flow distributions during the oscillation is measured from by using a single hole yawmeter with the phase locked sampling method to the oscillation. By compared with the results for higher solidity inducer, the behaviors of cavitation induced oscillation are clarified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.