Abstract

The ignition delay times of gas-phase kerosene/air mixtures were measured behind reflected shock waves,using side-wall pressure and CH * emission measurements in a heated shock tube.The experiments were performed over the temperature range of 1100-1500 K,at pressures of 2.0×10 5 and 4.0× 10 5 Pa,and for equivalence ratios(Φ)of 0.2,1.0,and 2.0.The effects of temperature,pressure,and equivalence ratio on the ignition delay time were investigated.The global activation energy for kerosene/air varies significantly when the equivalence ratio changes from 0.2 to 1.0,whereas the global activation energy at an equivalence ratio of 1.0 is almost the same as that at 2.0.Three correlations for the ignition delay time under three different equivalence ratios were deduced.The current data were compared with available kinetic mechanisms,and were found to be in good agreement with the predictions of Honnet et al. Chemical mechanism sensitivity analyses for different equivalence ratios were performed;the results showed that the ignition sensitivity at an equivalence ratio of 0.2 is quite different from those at 1.0 and 2.0.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.