Abstract
The present work is concerned a comparative study of the decay of swirling turbulent pipe flow downstream of three flow conditioners, the Etoile, the Tube bundle, and the Laws perforate plate, and its effect on accuracy of orifice plate flow meter. The swirl was generated by a double 90° degrees elbows in perpendicular planes. The discharge coefficients were measured with 3 different orifice meters with β = 0.5, 0.62, 0.70 at different Reynolds number. As a conclusion, the experimental study of the three flow conditioners used separately shows that the flow need longer distance for close to fully developed pipe flow and some errors, by reason of the swirl, on the discharge coefficient were inevitable for distance less 12D.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.