Abstract

A new beam-to-column connection for earthquake-resistant moment-resisting frames is introduced. The connection has a beam bottom flange friction device (BFFD) and posttensioned (PT) high-strength steel strands running parallel to the beam. The BFFD provides energy dissipation to the connection and avoids interference with the floor slab. The PT strands produce self-centering connection behavior. The connection behavior requires minimal inelastic deformation of the connection components and the beams and columns, and requires no field welding. A series of seven large-scale tests were performed to investigate the effect of the BFFD friction force, connection details, and the loading history on the performance of the connection under cyclic loading. The test results indicate that the BFFD provides reliable energy dissipation, and that the connection remains damage-free under the design earthquake.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.