Abstract

The pressure drop characteristics, dynamic column breakthrough, and pulsed-pressure-swing-adsorption (PPSA) experiments in an adsorption column packed with very fine 5A zeolite particles of mixed size in the range 63–75 μm are presented. A multipurpose experimental setup was designed and constructed to perform these experiments. The pressure drop and axial dispersion were very high in the adsorption column. Darcy’s equation and the correlation by Langer et al. were recalibrated to account for the increased pressure drop and enhanced axial dispersion, respectively. With these recalibrated constituent models, the numerical process model, solved using COMSOL Multiphysics software, was able to correctly capture the measured experimental breakthrough and PPSA performance results. The principal conclusion from this study is that the high axial dispersion and pressure drop in a column packed with very fine 5A zeolite particles are due to the surface roughness and clustering of the particles and channeling in the...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.