Abstract
Precast reinforced concrete (r.c.) structures can provide important advantages over their cast-in-place counterpart. However, lessons learned by past earthquakes evidence that beam-to-column joints may be a critical point of these structure and can undermine the seismic performance if not properly conceived. This paper presents a novel prestressed precast r.c. beam-to-column joint. The beam ends adjacent to the column are reinforced by steel jacket to prevent concrete from spalling. Steel strands are used to provide the joint with self-centering capacity. Replaceable mild steel bars provide the joint with energy dissipation capacity. The effectiveness of the proposed joint is investigated by experimental tests. The obtained results demonstrate the good properties of the joint in terms of strength and deformation capacity, control of story drift, easy reparability, and preventing beams and columns from damage. Finally, the comparison with a conventional cast-in-place beam-to-column joint points out the superior resilience against earthquake of the proposed precast prestressed joint.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.