Abstract

Cryogenic loop heat pipes (CLHPs) are effective and efficient cryogenic heat transport devices suitable for many space applications. In this work, a miniature cryogenic loop heat pipe (CLHP) with nitrogen as the working fluid was designed and experimentally investigated. An auxiliary loop was employed to assist the supercritical startup of the primary evaporator. The operational characteristics of the CLHP and the matching characteristics of heat loads applied to the primary and secondary evaporators were investigated experimentally. The results show that the CLHP can achieve reliably the supercritical startup when the heat load applied to the secondary evaporator is no less than 3W; when the heat load applied to the primary evaporator is no less than 2.5W, the primary evaporator can operate independently, otherwise a proper selection of the heat load applied to the secondary evaporator should be considered to overcome the parasitic heat load from the ambient. The CLHP is working at the variable conductance mode and can achieve smooth operational transition subject to a large step change of the heat load applied to the primary evaporator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.