Abstract
The experimental study was performed on five eccentric radial heat pipes with two outer-tube diameters. The test range can be given as follows, working fluid filling ratio Ω=44%∼83%, heat flux q=10000W/m2∼32000W/m2, and working temperature tv=50°C∼120°C. The correlations between radial heat pipe heat transfer performance and filling ratio, heat flux, working temperature were studied in the experiment. Based on linear regression of experimental data, the relationship between heat pipe equivalent heat resistance R and working temperature tv, heat flux q and filling ratio Ω was obtained.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.