Abstract
At the Shanghai Synchrotron Radiation Facility (SSRF), ultrafast experiments require picosecond temporal resolution. Thus, understanding the jitter of a single X-ray pulse is important. In this study, a timing synchronization control system that combines a timing system, optical fiber network, and X-ray streak camera detection system were employed to accurately acquire the temporal characteristics of a single X-ray pulse at a low photon intensity(103 photons/pulse). Experimental results showed that the intensity of a single X-ray pulse is distributed as a Gaussian curve in the longitudinal direction, and the pulse jitter broadens to approximately 5 ps, which is sufficient for ultrafast temporal resolution research at the SSRF.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.