Abstract
Start your abstract here... For a low specific speed centrifugal pump with the requirement of high efficiency of 68% and non-overload power characteristics, series experimental studies, by matching 9 volutes with 19 impellers were done. By combining the former research results about the splitters and the non-overload theory in centrifugal pump, the theoretical conditions to achieve the property of non-overload in a centrifugal pump with splitters was analyzed, and formulas to estimate the maximum shaft power and its position are derived. Based on the requirement of high efficiency and non-overload, blade outlet angle β 2, blade outlet width b 2, volute throat area Ft and the inlet diameter of splitters Di were chosen with three levels to design a normal L9 (34) orthogonal test scheme. Meanwhile, the optimized design scheme was determined, and corresponding test was done also, it demonstrates that the experiment purpose was reached, the design method to combine the splitters and non-overload theory is reasonable, which can get the property of high efficiency and non-overload.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.