Abstract

Abstract To improve the performance of the membrane process in the treatment of oily wastewater, the combined effects of pretreatment, membrane modification, and optimization of operating parameters on the microfiltration membrane system were investigated. First, coagulation and adsorption were used as pretreatment steps. Polyaluminium chloride and ferric chloride were employed as coagulants, and granular activated carbon was used as an adsorbent. In the optimal coagulation condition (1 g/L polyaluminium chloride, pH 7.5), chemical oxygen demand (COD) was reduced by 96%, while in the optimal adsorption condition, in which large amounts of activated carbon were utilized, 48% of COD was eliminated. A membrane of polyethersulfone containing SiO2-g-polymethacrylic acid (PMAA) nanoparticles was then prepared by the non-solvent-induced phase separation method. To reduce fouling and increase the flux of the membrane, the SiO2 nanoparticles were first activated with amine groups and then PMAA was grafted onto the surface of the particles. Subsequently, the operating parameters were studied to optimize the performance of the polyethersulfone (PES)/SiO2-g-PMAA membrane using the response surface methodology (RSM) method. The results indicated that the flux of the modified membrane for pretreated wastewater was 72.2% higher than that of the PES membrane and non-pretreated wastewater at an optimum pressure of 2 bar and a flow rate of 3.5 L/min.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call