Abstract
Isentropic efficiency of the nonequilibrium MHD power generator was studied by a shock tube driven disk generator. Cesium seeded helium was used as a working gas. From the measurements of Faraday current density distribution, it was possible to estimate the general tendency of Joule dissipation in the generator. The Joule dissipation did not decrease due to the occurrence of nonuniformity of the plasma when external load resistance was low, although it decreased with the decrease in the load resistance when the load resistance was high. The electrical efficiency increased with the increase in applied magnetic flux density. This fact is thought to be caused by high Hall parameter and the stabilization of the plasma due to high degree of seed ionization.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: IEEE Transactions on Plasma Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.