Natural convection heat transfer was investigated in a scaled test facility of a Trombe wall geometry. A silicone oil was employed as the convecting medium to obtain large Rayleigh numbers (up to 1.5 × 1010, based on enclosure height) characteristic of full-scale Trombe wall in a passive solar building. The main objectives were to study effects of Trombe wall nonisothermality and location on heat transfer, fluid temperature and fluid flow patterns. As expected, Nusselt numbers were slightly larger on the Trombe wall space side than on the living space side. Nusselt numbers increased slightly as the mass transfer gaps in the Trombe wall were increased. The results were verified, for the zero gap case, by comparing with previous studies. Physical understanding of the convection process was enhanced by flow visualization data. The information obtained should be useful to designers in optimizing overall building performance for passive solar heating.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.