Abstract
In industrial, aerospace, medical and other mission critical electronics employing high density interconnection PCBs, high DC voltage gradient and adverse environmental conditions facilitate Conductive Anodic Filament (CAF) formation. To prevent catastrophic failures caused by CAF short circuits, monitoring of manufacturing process and proper laminate selection is essential. The purpose of presented work was to evaluate CAF resistance level of FR4, low CTE, CAF resistant and BT/epoxy-based laminates. Test coupons comprising 90 potential hole-hole failure points with 250 μm spacing were fabricated and subjected to accelerated CAF test for 600 h in 85 °C, 87% RH. Surface insulation resistance measurements were performed to monitor coupons' condition. Time to failure of examined samples, microscopic inspection results and failure root-cause analysis are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.