Abstract

GLARE laminates with outstanding impact resistance, high fatigue resistance and a number of excellent performances are combined by ductile aluminum layers and high strength FRP layers. An experimental program was conducted to estimate the influence of geometric parameters, ply orientation and tightening torque on the performances of GLARE bolted joint. The study showed that the parameters of GLARE bolted joint have intrinsic properties of metal bolted joint and composite bolted joint. The design threshold values including of geometric parameters, ply orientation and tightening torque were given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.