Abstract

Repetitive use of a high-power-microwave radiation source implies strong erosion on cathode and anode materials. Electrode-material endurance has been studied in a series of experiments with an axial virtual cathode oscillator powered by a compact Marx generator. The Marx generator is operated in a 10-Hz repetitive mode with a burst of ten pulses. Velvet and graphite was used as electron-emitting materials, and they showed markedly different pulse characteristics. The following three different anode materials were used: stainless-steel mesh, stainless-steel wires, and molybdenum wires, which all had different influence on the pulse characteristics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.