Abstract

An acoustic field spontaneously induced in a thermoacoustic prime mover consisting of a looped tube and resonator is determined through simultaneously measurements of pressure P and velocity U. A thermal efficiency of the thermoacoustic prime mover of this type has been reported to reach 30%. The measurements of the acoustic field in the present system revealed that a phase lead of U relative to P takes a negative value of about −20° in the regenerator where the output power of the prime mover is generated. It was concluded that the possession of a negative phase lead at this position is taken as a clue in a significant increase in the output power. Moreover, the analysis in the thermoacoustic mechanism shows that a precise position for the location of a second regenerator acting as a heat pump exists in the looped tube. Indeed, by locating the second regenerator at the position, a thermoacoustic cooler was constructed. The thermoacoustic cooler could generate a low temperature of −25 °C without involving any moving parts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.