Demonstrated gas foil bearing (GFB) operation at high temperature is of interest for gas turbine applications. The effects of (high) shaft temperature on the structural stiffness and damping parameters of a foil bearing must be assessed experimentally. Presently, a hollow shaft warmed by an electric heater holds a floating 2nd generation FB that is loaded dynamically by an electromagnetic shaker. In tests with the shaft temperature up to 184°C, the measurements of dynamic load and ensuing FB deflection render the bearing structural parameters, stiffness and damping, as a function of excitation frequency and amplitude of motion. The identified FB stiffness and viscous damping coefficients increase with shaft temperature due to a reduction in the FB clearance. The bearing material structural loss factor, best representing mechanical energy dissipation, decreases slightly with shaft temperature while increasing with excitation frequency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.