Abstract
AbstractAs part of the Network for Earthquake Engineering Simulation Research (NEESR)-Grand Challenge Project Simulation of the Seismic Performance of Nonstructural Systems, an experimental program was carried out to evaluate the seismic responses, failure mechanisms, and fragilities of cold-formed steel framed gypsum partition walls. Understanding the seismic behavior of building interior partition walls is important because damage to these nonstructural components can initiate at relatively low story drift levels, potentially degrading the overall functionality of the building and contributing toward earthquake economic losses. To this end, in-plane quasi-static and dynamic tests were conducted on 36 partition walls constructed using common construction details. Variables examined on the 16 configurations tested include framing thicknesses, stud connections to top and bottom tracks, wall intersection details, and partial height walls among others. In addition, new details are proposed to increase the dr...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.