Abstract

Cross-laminated timber (CLT) manufacturing and construction has been steadily growing since its inception in Europe in the 1990s. In the US, the growth of the CLT adoption is inhibited by the lack of codified design provisions for CLT in high seismic regions. This led to a multi-year study conducted by Colorado State University to investigate suitable seismic design parameters of CLT shear wall systems. This paper presents the results from a series of shake-table tests featuring a full-scale two-story mass-timber building utilizing CLT Seismic Force Resisting Systems (SFRS). The building was designed using an R- factor equal to 4.0 under the equivalent lateral force procedure specifications of the ASCE 7-16 Standard. The test program included three phases with different wall configurations, reflecting different wall panel aspect ratios and the existence of transverse CLT walls. Test results indicate that the code-level life safety objective was achieved in all test configurations. The addition of transverse walls did not affect the ability of the panels to rock, and improved the performance of the building structural system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.