Core-ion temperature measurements are based on resolving the energy components and the analysis of fast neutrals coming out of the magnetic confinement of plasma. ADITYA-tokamak (R/a = 75 cm/25 cm) uses Neutral Particle Analyzer (NPA) based charge exchange diagnostic system for measurement of the core ion-temperature in the range of 100–300 eV of Aditya plasma. Several ohmic plasma discharges are investigated for the Aditya tokamak, which provides an estimate of core ion-temperature (Ti0) evaluation with time and its comparison with the core electron-temperature (Te0). The analysis shows the ratio of Ti0/Te0 is typically in the rage of 30%–40%. Attempts have been made to estimate the neutral hydrogen (nH°) density in the core regime and its evolution with time using a simple approach. The core neutral densities estimated in the order of 108–109 cm−3 for ohmic discharges in ADITYA-tokamak. Effect of the ion cyclotron radio frequency heating (ICRH) on the experimental charge-exchange spectrum is also observed, which shows a typical increase of the perpendicular ion temperature (Ti⊥) by ~ 50 eV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.