Abstract

Vibration damping is an effective strategy to enhance the life-cycle and performance of mechanical components. In this regard passive control systems involve lower costs and are easier to implement but their bandwidth is limited, whereas active systems provide larger bandwidth and higher adaptability to dynamic loads but higher costs and complexity are required. The recent advances in smart materials promoted the development of smart structures suitable for vibration damping and control. Between them the piezoelectric systems seem to be the most promising, however their efficiency relies on their placement. In a previous work the authors proposed and validated an analytical method to detect the optimal location of piezoelectric plates to control the multi-modal vibrations of a cantilever beam. Recent findings show that, if all actuators are activated simultaneously, the optimization problem can be traced back to the determination of the optimal potential distribution on all the piezoelectric actuators. In this paper the above method is taken into account and applied to a cantilever beam with 13 pairs of surface mounted PZT plates under the excitation provided by an electrodynamic shaker. The experimental damping of two flexural modes combinations has been performed by means of a special-purpose workbench and the assessment of the damping efficiency has been measured by means of a micro I.C.P. accelerometer. The results showed that the multimode vibrations of the cantilever beam can be efficiently damped if the potential distribution on all the PZT plates is optimized.

Highlights

  • The vibration control is one of the main challenges in many engineering fields

  • In this paper the above method is taken into account and applied to a cantilever beam with 13 pairs of surface mounted PZT plates under the excitation provided by an electrodynamic shaker

  • The results showed that the multimode vibrations of the cantilever beam can be efficiently damped if the potential distribution on all the PZT plates is optimized

Read more

Summary

Introduction

The vibration control is one of the main challenges in many engineering fields. The structural vibrations may weaken the fatigue resistance and decrease the life-cycle of mechanical parts, so as to lead to the failure in the worst cases. This model has been further implemented in [9] with all the piezo actuators continuously activated and the optimization problem has been traced back to the identification of the optimal potential distribution on the elements that cover the beam. The outcomes confirm that the multimode vibrations of a beam could be efficiently damped if the best potential distribution on all the PZT actuators is provided

Methods
Results
Conclusion
Full Text