Abstract
AbstractThis paper presents an experimental program to investigate the progressive collapse resistance of reinforced-concrete (RC) building structures subjected to a loss of a penultimate-external (PE) column that is the exterior one nearest to the building corner. Under this accidental scenario, any mobilization of catenary action in beams and slabs bridging over the column, as an alternative load path, should rely solely on the strength of a half perimeter compressive ring forming within the deflected slab area. Three one-third scaled beam-slab substructures were designed, built, and tested by a static loading scheme to examine the overall load capacity and displacement ductility that are two aspects of the progressive collapse resistance of RC building structures. The test variables are (1) additional amounts of beam stirrups, (2) additional beam longitudinal reinforcement, and (3) the aspect ratio of the slab panel. The boundary condition of the specimens is rotationally and vertically restrained, but...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.